Method Development and Validation of Assay of Molnupiravir in Molnupiravir Capsules by RP-HPLC
Sumit Agarwal1, Rajasekaran Sidhan2
- 1Department of Pharmaceutics, Bhagwant University, Sikar, Ajmer, Rajasthan, INDIA.
- 2Department of Pharmacology, Bhagwant University, Sikar, Ajmer, Rajasthan, INDIA.
Abstract
Background: Method was developed and validated for performing Assay of Molnupiravir in Molnupiravir Capsules Materials and Methods: RP-HPLC with an auto sampler and 15 cm x 4.6 mm, 5 µm L1 (C18) column (Make: Intek Chromasol, Model: Chromasol Jade C18). 0.1% ortho phosphoric acid buffer, acetonitrile and methanol in ratio 80: 16: 04% was used as mobile phase and HPLC grade water was used as diluent. Flow rate and injection volume were 0.8 mL/min and 5 µL respectively. Detection wave length was 237 nm.Results: The method was found to be specific without any interference from blank, placebo, mobile phase solution and impurities. % RSD of six samples was 1.01 indicating the precision of the method. Accuracy and linearity of the method were determined over the concentration range of 50 to 150%. The mean % recovery was found to be 99.66%, Correlation coefficient (R2) was found to be 0.9999. The method remained unaffected by the small changes in analytical method parameters like variation in flow rate±0.2 mL/min, temperature±2ºC and wavelength±2 nm indicating the robustness of the method.Conclusion: The method was novel and simple with a run time of 10 min, hence can be utilized in industries for Assay of Molnupiravir in Molnupiravir Capsules.
Keywords: Assay; COVID-19; Molnupiravir Capsules; RP-HPLC
FULL TEXT
INTRODUCTION
Molnupiravir is an oral antiviral medication used to treat COVID-19 in individuals infected with SARS-CoV-2.1,5 It is a prodrug that is metabolized into N4-hydroxycytidine, a synthetic nucleoside derivative. Chemical structure of Molnupiravir was provided in Figure 1. Once activated, Molnupiravir interferes with the replication of the virus by causing errors in the viral RNA. This leads to the formation of defective viral genomes, which impairs the virus's ability to reproduce. As a result, the viral load is reduced, helping to manage the infection effectively.6,8 The current paper discusses the method development and validation of Assay method for quantitative estimation of Molnupiravir in Molnupiravir Capsules by RP-HPLC.9,10
MATERIALS AND METHODS
Chemicals and Reagents
Molnupiravir API, Molnupiravir capsules- 200 mg, Ortho phosphoric acid, Methanol, Acetonitrile, HPLC grade Water.
Instrumentation
Analytical Weighing Balance, Sonicator, HPLC (With Auto Sampler)- Prominence - i LC-2030C Plus.
Chromatographic Conditions
Column: 15 cm x 4.6 mm, 5 µm L1 (C18) (Make: Intek Chromasol, Model: Chromasol Jade C18).
Flow Rate: 0.8 mL/min Wave Length: 237 nm Injection Volume: 5 µL Temperature: 40ºC Run Time: 10 min.
Diluent: HPLC grade Water
Preparation of Buffer Solution
Accurately transferred 1 mL of Ortho phosphoric acid into 1-L HPLC grade water, shaken and mixed well. Filtered through 0.45 µ filter, sonicated to degas.
Preparation of Mobile Phase
Buffer solution: Acetonitrile: Methanol (80: 16: 04%).
Preparation of Standard Stock Solution
Weighed and transferred 25 mg Molnupiravir working standard into 50 mL volumetric flask, added 20 mL of diluent and sonicated to dissolve, volume was made up to mark with diluent.
Preparation of Standard Solution
Diluted 10 mL of standard stock solution to 50 mL with diluent.
Preparation of Sample Stock Solution
Dissolved a weighed quantity of mixed contents of 20 capsules containing equivalent to about 25 mg of Molnupiravir in 50 mL volumetric flask by adding 20 mL of diluent and sonicating. Volume was made up to mark with diluent, mixed well and filtered.
Preparation of Sample Solution
Diluted 10 mL of filtered sample stock solution to 50 mL with diluent.
Spiked Sample Preparation
Diluted 10 mL of sample stock solution and 10 mL of standard stock solution to 50 mL with diluent.
Placebo Stock Preparation
Weighed accurately equivalent to 25 mg of placebo in 50 mL volumetric flask, added 20 mL diluent and shaken with aid of ultrasound for 15 min and diluted to volume with diluent and filtered.
Placebo Preparation
Diluted 10 mL of filtered placebo stock solution to 50 mL with diluent.
Method validation
The method developed was validated as per ICH Q2(R1) guidelines to check System Suitability, Specificity, Linearity, Accuracy, Precision, Robustness.7
RESULTS
System Suitability
The % RSD for peak areas was 0.09 for five replicate injections of Molnupiravir Standard, tailing factor was 1.099, Plate count was 75314. From the results of Table 1 it was concluded that system was meeting the System Suitability acceptance criteria.
Specificity
No interference from blank, mobile phase, placebo and impurities peaks was observed at the retention time of Molnupiravir peak which was evident from the results of Table 2. Thus specificity of the method was conformed (Figures 2-7).
Chromatogram of Spiked Sample.
Linearity
The method was found to be linear over the concentration of 50% to 150% with a Correlation Coefficient (R2) 0.9999 (Figure 8 and Table 3).
Accuracy
The Recovery values were found between 99.31% to 99.89% over the three concentration levels with a mean % Recovery of 99.66% and % RSD 0.21 conforming the Accuracy of method (Table 4).
Method Precision
The % RSD of six sample preparations of Molnupiravir Capsules was found to be 1.01 and Mean % Assay was 100.03 conforming the precision of the method which was evident from Table 5.
Robustness
Robustness of the method was investigated by varying analytical method parameters like flow rate ±0.2 mL/min, temperature ±2ºC and wavelength ±2 nm. From the results of Table 6 the method was found to be robust.
| Parameter | Observed value |
|---|---|
| Tailing factor | 1.099 |
| Plate count | 75314 |
| Retention time | 6.87 |
| Parameter | Observed value |
| %RSD (peak areas) | 0.09 |
| Sample Name | Inference |
|---|---|
| Blank | No interference was observed from Blank at retention time of Molnupiravir Peak. |
| Mobile Phase Solution | No interference was observed from Mobile Phase |
| Placebo | No interference was observed from Placebo at retention time of Molnupiravir Peak. |
| Impurities | No interference was observed from Impurities peaks at retention time of Molnupiravir Peak. |
| Concentration Level of Molnupiravir | Peak Areas of Molnupiravir |
|---|---|
| 50% | 671304 |
| 75% | 996737 |
| 100% | 1321453 |
| 125% | 1640390 |
| 150% | 1983903 |
| Correlation coefficient (R2) of Molnupiravir | 0.9999 |
| % Level | % Recovered |
|---|---|
| 50 | 99.89 |
| 99.73 | |
| 99.57 | |
| 100 | 99.31 |
| 99.72 | |
| 99.38 | |
| 150 | 99.82 |
| 99.65 | |
| 99.87 | |
| Mean % Recovery | 99.66 |
| % RSD | 0.21 |
| Sample Number | % Assay of Molnupiravir |
|---|---|
| 1 | 100.04 |
| 2 | 100.56 |
| 3 | 99.80 |
| 4 | 101.47 |
| 5 | 98.41 |
| 6 | 99.88 |
| Mean | 100.03 |
| % RSD | 1.01 |
| Lower variation | Actual | Higher variation | |
|---|---|---|---|
| % Assay | |||
| 100.24 | 100.31 | 100.39 | |
| 100.47 | 100.42 | 100.48 | |
| 98.76 | 98.68 | 98.53 |
DISCUSSION
The method was validated as per ICH Q2 (R1) guidelines, demonstrating excellent specificity, precision, accuracy and linearity across the concentration range of 50-150% which was evident from the Results
CONCLUSION
A RP-HPLC method was developed and validated for Assay of Molnupiravir in Molnupiravir Capsules. The method was found to be specific without any interference from blank, placebo, mobile phase solution and impurities. % RSD of six samples was 1.01 indicating the precision of the method. Accuracy and linearity of the method were determined over the concentration range of 50 to 150%. Correlation coefficient (R2) was found to be 0.9999. The method remained unaffected by the small changes in analytical method parameters like variation in flow rate ±0.2 mL/min, temperature ±2ºC and wavelength ±2 nm indicating the robustness of the method. The Method was novel and simple with a run time of 10 min, hence can be utilized in industries for Assay of Molnupiravir in Molnupiravir Capsules.
SUMMARY
A Reverse-Phase High-Performance Liquid Chromatography (RP-HPLC) method was developed and validated for the quantitative estimation of Molnupiravir in capsule dosage form. The separation was achieved using a C18 column (15 cm × 4.6 mm, 5 µm) with a mobile phase consisting of 0.1% orthophosphoric acid buffer, acetonitrile, and methanol in the ratio of 80:16:04 (%v/v). The method utilized a flow rate of 0.8 mL/min, detection at 237 nm, and an injection volume of 5 µL.
The method was validated as per ICH Q2 (R1) guidelines, demonstrating excellent specificity, precision (%RSD=1.01), accuracy (mean recovery=99.66%), and linearity (R²=0.9999) across the concentration range of 50-150%. The method was robust against small deliberate variations in flow rate, temperature, and detection wavelength. The total runtime of 10 min makes the method efficient and suitable for routine quality control analysis in the pharmaceutical industry.
Abbreviations
RP-HPLC: Reverse Phase High Performance Liquid Chromatography; API: Active Pharmaceutical Ingredient; ICH: International Council for Harmonisation; RSD: Relative Standard Deviation; UV: Ultraviolet; Nm: Nanometer; µL: Microliter; mL: Milliliter; %RSD: Percent Relative Standard Deviation; HPLC: High Performance Liquid Chromatography; ºC: Degree Centigrade; SARS-CoV-2: Severe Acute Respiratory Syndrome Coronavirus 2; COVID-19: Coronavirus Disease 2019.
Acknowledgement
We express our sincere gratitude to Department of Pharmaceutics, Department of Pharmacology, Bhagwant University, Sikar Rd and Sain Medicaments Pvt. Ltd., Telangana for providing constant support, guidance and facilities to carry out the research work.
Funding
We express our heartfelt thanks to Sain Medicaments Pvt. Ltd., Telangana for providing the facilities and required funding to carry out the research work.
Conflict of Interest
The authors declare that there is no conflict of interest.