Development and Validation of a HPLC-PDA Method to Quantification of Ketobemidone in Rat Plasma and its’ Application in Pharmacokinetic Study
1, 3, 2, 2, 2, 4, 4, 2
- 1Department of Chemistry, School of Applied Science and Humanities, Vignan’s Foundation for Science, Technology and Research, Vadlamudi, Guntur, Andhra Pradesh, India.
- 2Discovery Analytical R and D Department, Aragen Life Sciences Pvt. Ltd., IDA Nacharam, Hyderabad, Telangana, INDIA.
- 3Polymer Engineering Laboratory, Department of Chemistry, PSG Institute of Technology and Applied Research, Neelambur, Coimbatore, Tamil Nadu, INDIA.
- 4Department of Freshmen Engineering, St. Martin’s Engineering College, Dhulapally, Hyderabad, Telangana, INDIA.
CORRESPONDENCE
Dr. Subramani Devaraju
Department of Chemistry School of Applied Science and Humanities, Vignan's Foundation for Science, Technology and Research, Vadlamudi, Guntur-522213, Andhra Pradesh, INDIA.
Received: 16-05-2024; Revised: 05-09-2024; Accepted: 02-01-2025.
Volume 59, Issue 2s (Supplement) · pp. s740-s747 · 2025 · DOI: 10.5530/ijper.20256924
ABSTRACT
Aim: Ketobemidone is an opioid drug that have been using against pain in various circumstances. The current research was aimed to develop and validate a HPLC-PDA method to estimate the ketobemidone in rat plasma.Materials and Methods: The ketobemidone in the biological matrices (rat plasma) was separated using solvent extraction method using methanol as extracting solvent. An isocratic mobile phase consisting of methanol-water-phosphate buffer at 40:60:0.01 % v/v/v and Kromasil C18 column were used for separation in Liquid Chromatography (LC).Results: The selected linearity range i.e., 0.10-25μg/mL was acceptable with r2 value 0.9998 as least square method. The determined Lower Limit of Quantification (LLOQ) is 0.10 μg/mL. The intermediate precision studies were performed within and between days; and the data obtained are within a significant range, i.e., %RSD <9.2 and the accuracy was within 10.0% of the relative error.Conclusion: The developed method to detect the ketobemidone was successfully validated and it was successfully applied on rat pharmacokinetic study.
KEYWORDS
REFERENCES
As publishedShowing references and in-text citations exactly as published.
Cite this article
SELECT FORMAT
Aitha, S., Devaraju, S., Murthy, J. N. S. R. C., Tatapudi, K. K., Geddada, L. P., Somasekhar, T., Sadasivuni, H., & Kaliyaperumal, M. (2025). Development and Validation of a HPLC-PDA Method to Quantification of Ketobemidone in Rat Plasma and its’ Application in Pharmacokinetic Study. Indian Journal of Pharmaceutical Education and Research, 59(2s), s740-s747. https://doi.org/10.5530/ijper.20256924
Copyright and licence
© 2025 Author(s)
This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 License, which permits unrestricted use, distribution and reproduction in any medium, provided the original author and source are credited. CC BY 4.0